Detalles del producto
Lugar de origen: Porcelana
Nombre de la marca: RION
Certificación: CE, FCC , ROHS
Número de modelo: HCA716S / HCA726S
El documento: HCA716 HCA726-CANBUS TILT S...OR.pdf
Pago y términos de envío
Cantidad de orden mínima: 1
Precio: $225.00pcs/Pieces
Detalles de empaquetado: Cartón que embala
Tiempo de entrega: 5 ~ 8 días de trabajo
Condiciones de pago: T/T
Capacidad de la fuente: 1000 unidades/mes
Funcionamiento amplio de la temperatura: |
-40~+85℃ |
Exactitud: |
refiera a los datos técnicos |
Tamaño pequeño: |
54 × 46 × 20,5 mm (personalizado) |
Interfaz: |
CAN2.0A/CAN2.0B |
Funcionamiento amplio de la temperatura: |
-40~+85℃ |
Exactitud: |
refiera a los datos técnicos |
Tamaño pequeño: |
54 × 46 × 20,5 mm (personalizado) |
Interfaz: |
CAN2.0A/CAN2.0B |
HCA716S / HCA726S is a small volume high-precision single / dualaxis inclinometer developed by RION Technology for industrial field control. It adopts CAN2.0A/B serial access interface. Built-in high-precision 24bit A / D differential converter, through the 5th order filtering algorithm, can measure the tilt and pitch angle of the sensor output relative to the horizontal plane. The product integrates the latest technology main MEMS tilting unit, the measuring range up to ± 180 °, and the full-scale accuracy is 0.01 °, which can easily achieve dual-axis and single-axis tilt measurement. The product belongs to a real industrial grade product, with reliable and stable performance, good scalability, and multiple output options. It is suitable for the application of monitoring of ancient buildings, dilapidated buildings, ancient walls, etc., and large-scale high-precision measurement in industrial sites.
| HCA716/726-C2/C3 | CONDITION | PARAMETER | UNIT | |||||
|---|---|---|---|---|---|---|---|---|
| Measure range | ±10 | ±30 | ±60 | ±90 | ±180 | ° | ||
| Measure axis | X Y | X Y | X Y | X Y | Vertical X axis | axis | ||
| Resolution | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 | ° | ||
| Measure accuracy | MAXE | Room temp. | 0.008 | 0.01 | 0.01 | 0.02 | 0.02 | ° |
| RMSE | Room temp. | 0.004 | 0.005 | 0.005 | 0.006 | 0.006 | ° | |
| Long temp. stability | <0.02 | <0.02 | <0.02 | <0.02 | <0.02 | ° | ||
| Zero Temp.coefficient | -40~85℃ | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 | °/℃ | |
| Sensitivity temp-coeffi | -40~85℃ | ≤0.01 | ≤0.01 | ≤0.01 | ≤0.01 | ≤0.01 | %/℃ | |
| Power on time | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | S | ||
| Response frequency | 20 | 20 | 20 | 20 | 20 | Hz | ||
| Interface | CAN2.0A/CAN2.0B | |||||||
| EMC | According to EN61000 and GBT17626 | |||||||
| MTBF | ≥98000 Hours/times | |||||||
| Insulation Resistance | ≥100M | |||||||
| Shockproof | 100g@11ms, 3 Axial Direction (Half Sinusoid) | |||||||
| Anti-vibration | 10grms, 10~1000Hz | |||||||
| Protection grade | IP67 | |||||||
| Cables | Standard 1M length / wear proof / grease proofing / wide temperature, Shielded cables 4*0.2mm2 | |||||||
| Weight | ≤150g (including 1 meter cable) | |||||||